簡要描述:德國TURCK浪涌保護器,圖爾克Surge Protector安裝說明浪涌保護器安裝在接口設(shè)備之前并提供的電壓浪涌防護能力。僅6.2mm寬的DIN導軌設(shè)備為IP20防護等,可用于非本安區(qū)域和本安區(qū)域。
Product category
Related articles
德國TURCK浪涌保護器,圖爾克Surge Protector安裝說明
TURCK部分型號列表
HT-WWAK3-5-HT-WWAS3/S2430
HT-WWAK4.5-10-HT-WWAS4.5/S2430
HT-WWAK4.5-2/S2430
HT-WWAK4.5-2-HT-WWAS4.5/S2430
HT-WWAK4.5-5/S2430
HT-WWAK4.5-5-HT-WWAS4.5/S2430
HT-WWAK4-10/S2430
HT-WWAK4-10-HT-WWAS4/S2430
HT-WWAK4-2/S2430
HT-WWAK4-2-HT-WWAS4/S2430
HT-WWAK4-5/S2430
HT-WWAK4-5-HT-WWAS4/S2430
HT-WWAS3-10/S2430
HT-WWAS3-2/S2430
HT-WWAS3-5/S2430
HT-WWAS4.5-10/S2430
HT-WWAS4.5-2/S2430
HT-WWAS4.5-5/S2430
HT-WWAS4-10/S2430
HT-WWAS4-2/S2430
HT-WWAS4-5/S2430
I/O-ASSISTANT-KABEL-BL20/BL67
I/O-ASSISTANT-KABEL-PICONET
IA1.53SMTA
IA23S
IF23S
IM1-121EX-R
IM1-121EX-T
IM1-12EX-MT
IM1-12EX-R
IM1-12EX-T
IM1-12-T
IM12-22EX-R
IM12-22EX-R/230VAC
IM12-22EX-R/24VDC
IM1-22EX-MT
德國TURCK浪涌保護器,圖爾克Surge Protector安裝說明
TURCK浪涌保護器安裝說明(圖)
■ ATEX, IECEx, UL, TR CU
■ 工作電壓24 VDC
■ 用于 1 路 2 線浮點信號回路
■ IEC 類別:C1 / C2 / C3 / D1
■ 可燃性等V-0
■ HART®
可傳輸
防爆型號 是
ATEX防爆型, IECEx, UL
功能安全(SIL/PL) SIL2
標稱電壓 24 VDC
防護等 IP20
產(chǎn)品系列 IMSP
機械數(shù)據(jù)
防護等 IP20
符合UL 94標準的阻燃等 V-0
工作溫度 -40…+80 °C
儲藏溫度 -40…+80 °C
尺寸 93.1 x 6.2 x 102.5 mm
重量 44 g
安裝說明 DIN 導軌 (NS35)
外殼材料 塑料
電氣連接 螺紋連接端子
端子橫截面 2.5 mm2
固定扭矩 0.8 Nm
標稱電壓Un 24 VDC
IEC category C1; C2; C3; D1
避雷器,交流額定電壓Uc 25 VAC
避雷器,直流額定電壓Uc 36 VDC
Nominal current In (ð 40 °C) 350 mA
有源電流c 含 Uc 2 μA
Leakage current acc. to PE with given Uc 2 μA
標稱放電電流 In (8/20) μs (線-線) 5 kA
標稱放電電流 In (8/20) μs (線-地) 5 kA
浪涌電流總計 (8/20) μs 20 kA
浪涌電流總計 (10/350) μs 1 kA
放電電流Izui大值 (8/20)μs(芯對芯) 10 kA
放電電流Izui大值 (8/20)μs(芯對地) 10 kA
額定脈沖電流 Ian (10/1000) μs (線-線) 50 A
額定脈沖電流 Ian (10/1000) μs (線-地) 50 A
Cutoff frequency fg (3dB), asym. (GND) 50ò system 類型 6 MHz
Cutoff frequency fg (3dB), asym. (GND) 150ò system Typ. 2 MHz
Capacitance ð1.3 nF (per path)
Resistance per path 3,3 ò 20%
Required backup fuse, max. 315 mA
浪涌電流阻抗符合EC 61643-21 (線圈-線圈) C2 (10 kV / 5 kA); C3 (25 A)
浪涌電流阻抗符合EC 61643-21 (線圈-線圈) C2 (10 kV / 5 kA); C3 (25 A); D1 (500 A)
AC protection acc. to IEC 61643-21 5 A - 1 s
Standards for air and creepage distances IEC 60664-1 / EN60079-11
Standards/Regulations IEC 61643-21 / DIN EN 61643-21
Lightning test current (10/350)μs, peak current Iimp 500 A
Output voltage limitation 1kV/μs (core-to-core) ð 60 V
Output voltage limitation 1kV/μs (core-to-earth) ð 650 V
Residual voltage In (core-to-core) ð 70 V
Residual voltage Ian (core-to-core) ð 50 V
保護等UP C2 - 10 kV/5 kA (線-線) ð 70 V (C2 - 10 kV / 5 kA)
保護等UP C3 - 10 A (線-線) ð 50 V (C3 - 10 A)
保護等UP D1 - 500 A (線-線) ð 80 V (D1 - 500 A)
保護等UP C1 - 500 V/250 A (線-地) ð 650 V (C1 - 500 V / 250 A)
保護等UP C2 - 10 kV/5 kA (線-地) ð 700 V (C2 - 10kV / 5 kA)
保護等UP D1 - 500 A (線-地) ð700 V (D1 - 500 A)
響應(yīng)時間 tA (core-to-core) ð 1 ns
響應(yīng)時間 tA (core-to-earth) ð 100 ns
Insertion loss aE, sym. Typ 0,7 dB (1 MHz / 50 ò)
Insertion loss aE, sym. Typ. 0,3 dB (350 MHz / 15